Skip to main content

Key Findings

Enchant Energy's claims about the efficiency of a carbon capture installation at the San Juan Generating Station in New Mexico are exaggerated

An IEEFA analysis finds the effective carbon dioxide capture rate at San Juan -- after including its mine emissions -- would be no more than 72%, not the 90% that Enchant claims

Enchant acknowledges there is little investor interest in its carbon capture project and it will be asking for $1 billion from the federal government

Executive Summary

VIEW REPORT WEBINAR

The U.S. Department of Energy (DOE) has issued a notice of intent to fund six carbon capture demonstration projects. Two are to be located at new or existing coal-fired generators, two at new or existing gas-fired facilities, and two at new or existing industrial facilities not proposed for electric generation.

DOE says it intends to evaluate the full life cycle emissions for each funding application and “will give preference to applications that reduce GHG [greenhouse gas] emissions to the greatest extent across the full end-to-end project inclusive of upstream and downstream emissions.” DOE also says projects must achieve a minimum unit-widecarbon dioxide (CO2) capture rate of 95%“once stable operations are achieved.”

Like other proponents of carbon capture and storage (CCS) seeking federal funding of their projects, Enchant Energy and its allies claim that retrofitting the San Juan Generating Station (SJGS) in New Mexico for carbon capture could capture 90% or more of the CO2 emitted by the power plant. Real-world evidence suggests that this carbon capture rate is unrealistically high. Yet even if it were achievable, the total climate impact of SJGS would still be significant because of the substantial methane emissions from the San Juan coal mine that supplies fuel to the station.

Our analysis finds that the effective CO2 capture rate at the plant after including the mine’s methane emissions would be no more than 72%. The figure is likely too high, since it assumes Enchant will be able to consistently capture 95% of CO2 generated at the plant. 

IEEFA has chosen to focus on Enchant’s proposed project for three reasons. First, there is publicly available data on the production and emissions at both the plant and the mine. Second, Enchant has acknowledged that there is very limited investor interest in its carbon capture project; consequently, it will be seeking almost $1 billion in funding from the federal government. Finally, San Juan’s current owners have decided that the plant is no longer economical to operate and should be retired this year.IEEFA’s analysis concludes:

  1. Even if Enchant captures 90% of the CO2 produced by SJGS, the combined CO2-equivalent (CO2e) capture rate for both the mine and the plant would be only 68%. In this scenario, the project would continue to emit more than 3 million tons of CO2-equivalents annually.
  2. If Enchant were able to capture only 75% of the CO2produced by SJGS, the effective capture rate for both the mine and the plant would be 57%.
  3. If Enchant were able to capture only 65% of the CO2 produced by SJGS, the effective capture rate for both the mine and the plant would be 49%.

As disappointing as these findings may be to carbon capture advocates, they likely substantially understate the SJGS project’s total climate effects. In addition to uncaptured CO2 from the power plant and significant methane emissions from the San Juan coal mine, CO2 can leak during transportation to a storage site, and may also leak from underground storage facilities. In addition, if SJGS carbon were used for enhanced oil recovery (EOR) projects, significant additional volumes of CO2 would be released during the production process and through consumption (CO2 leakage and the CO2 emissions from EOR are not considered in this analysis).

The problem of associated methane emissions is endemic not only to SJGS, but also to other coal and natural gas plants where carbon capture is being proposed, as well as to “blue,” or natural gas-fired hydrogen projects that are seeking state and federal subsidies. For example, in the case of a gas-fired generator, even if a 90% capture rate is achieved over the long term, there are still likely to be significant methane leaks during production of the natural gas and its transportation to the generator, as well as from CO2 pipelines and the underground storage facility.

VIEW REPORT WEBINAR

Carbon capture's methane problem

 

David Schlissel

David Schlissel is an IEEFA analyst with 50 years of experience as an economic and technical consultant on energy and environmental issues. 

He has testified as an expert witness before regulatory commissions in more than 35 states and before the U.S. Federal Energy Regulatory Commission and the Nuclear Regulatory Commission.

Go to Profile

Dennis Wamsted

At IEEFA, Dennis Wamsted focuses on the ongoing transition away from fossil fuels to green generation resources, focusing particularly on the electric power sector.

Go to Profile

Join our newsletter

Keep up to date with all the latest from IEEFA